PDA

View Full Version : Accumulated interference power for PRB



dannthemann
2019-04-15, 06:06 PM
Hi, according to vendor doc, the following parameters

pmRadioRecInterferencePwrPrb1
The accumulated interference power for PRB1

Unit: mW * 2^(-44)

Scanner: Not included in any predefined scanner




Condition: Samples summed over the measurement period. Measurements are averaged over receive antennas. One sample for each PRB per 40ms.

Counter type: CC/SUM

Counter is reset after measurement period: Yes

How can I convert them to dBm?

If I apply directly factor 2^(-44) the values make no sense.

For example, for CELL_1 the value of PMRADIORECINTERFERENCEPWRPRB1 for DAY_1 is

166744963

If factor 2^(-44) is applied the mW value is


9.47835E-06



and in dBm the value is -50.23 which makes no sense.

41955

Thanks in advance.

dannthemann
2019-04-26, 07:07 PM
Hi, any idea how to convert this counter into dBm?

Thanks

pmRadioRecInterferencePwrPrb1The accumulated interference power for PRB1
Unit: mW * 2^(-44)
Scanner: Not included in any predefined scanner
Condition: Samples summed over the measurement period. Measurements are averaged over receive antennas. One sample for each PRB per 40ms.
Counter type: CC/SUM
Counter is reset after measurement period: Yes