PDA

View Full Version : Question No contact with opposite terminal? But RSL are OK( -30) / Huawei RTN905



sackyharrey
2018-07-26, 12:17 PM
Hello dear Member.
My team started to align a MW link (HUAWEI RTN 905, 23GHz). RSLs are -30 for site and FarEnd but we still have no contact with the opposite terminal(site). They already double-checked frequencies .
Did someone face this problem before? Any idea about this probleme?

mariosulcaj
2018-07-26, 07:03 PM
The icons are all green ?

sackyharrey
2018-07-26, 07:54 PM
The icons are all green ?
Hi,
Yes, all icons are green.

uel888
2018-07-26, 09:47 PM
Try to reset both radio! :-)

simog72
2018-07-27, 10:09 PM
try to use other brand !
:D

I m joking !!

bioda
2018-08-06, 05:54 PM
Hi,

Check the Modulation scheme/capacity configured.I think it's not same on both sites.

rm77
2018-08-07, 05:56 PM
Have you checked if there are any interference , you can do it by scan frequency from U2000.

jndomingo
2018-08-30, 03:46 AM
For isolation purposes. Can you Ping IP on the other sides? is the correct IP on both end are in the-same IP Block.