PDA

View Full Version : Question RET Adjustment on Huawei Platform U2000



deekeyz
2016-07-31, 10:56 PM
Good day All,

Please can anyone share or point me to any document on how to do the RET Adjustment on Huawei U2000 platform.

Many thanks.

BR,
Deekeyz

justdream
2016-08-01, 04:43 AM
Use MML Command:
DSP RETSUBUNIT

mohammed Gh.
2016-08-01, 06:58 PM
@deekezy

Enjoy below procedure :)

Report Type = Scan ALD
Status = Success
Session ID = 65543

Result
------
Control Port Cabinet No. Control Port Subrack No. Control Port Slot No. Control Port No. Result ALD Device Type Vendor Code Serial No. Protocol Version Configure Status Subunit Number Failure Cause

0 60 0 RET SUCCESS SINGLE_RET HW M0997F600SR6400yL AISG2.0 UNCONFIGURED 1 NULL
0 60 0 RET SUCCESS SINGLE_RET HW M0997F600SS334yyR AISG2.0 UNCONFIGURED 1 NULL
0 61 0 RET SUCCESS SINGLE_RET HW M0997F600NR6910yL AISG2.0 UNCONFIGURED 1 NULL
0 61 0 RET SUCCESS SINGLE_RET HW M0997F600NS843yyR AISG2.0 UNCONFIGURED 1 NULL
0 62 0 RET SUCCESS SINGLE_RET HW M0997F600RU5946yL AISG2.0 UNCONFIGURED 1 NULL
0 62 0 RET SUCCESS SINGLE_RET HW M0997F600RV037yyR AISG2.0 UNCONFIGURED 1 NULL
(Number of results = 6)

--- END


+++ HUAWEI 2016-01-14 09:19:04
O&M #667
%%/*800481*/CLB RET:OPMODE=SUBUNIT,DEVICENO=0,SUBUNITNO=1;%%
RETCODE = 0 Progress report, Operation succeeded.

Report Type = Calibrate RET
Status = Start
Session ID = 65544

--- END


+++ HUAWEI 2016-01-14 09:20:54
O&M #671
%%/*800485*/CLB RET:OPMODE=SUBUNIT,DEVICENO=2,SUBUNITNO=1;%%
RETCODE = 0 Progress report, Operation succeeded.

Report Type = Calibrate RET
Status = Success
Session ID = 65546

Result
------
Device No. Subunit No. Result

2 1 SUCCESS
(Number of results = 1)

--- END


O&M #746
%%/*800661*/DSP RET:;%%
RETCODE = 0 Operation succeeded.


Display RET Dynamic Information
-------------------------------
Device No. Actual Vendor Code Actual Device Serial No. Actual Subunit Number Control Port Cabinet No. Control Port Subrack No. Control Port Slot No. Control Port No.


0 HW M0997F600SR6400yL 1 0 60 0 NULL
1 HW M0997F600NR6910yL 1 0 61 0 NULL
2 HW M0997F600RU5946yL 1 0 62 0 NULL
(Number of results = 3)




--- ENDDSP RETSUBUNIT:;

tharinduwije
2016-08-01, 09:45 PM
if you want to adjust RET use MOD RETSUBUNIT command.Make sure you check the RET supported MAX tilt values using DSP RETDEVICEDATA command to make sure you are not setting tilt beyond device capability.....For TMA use DSP TMA & DSP TMA SUBUNIT to see the Gains.Further you can set the attenunation using MOD RXBRANCH command