PDA

View Full Version : Question Unbalace of FACH and DCH UE between 2 carriers



fahmi
2014-12-10, 10:15 PM
Hi all,

I have 2 carriers of the same sector that shows unbalace of FACH and DCH UEs while HSPA UEs is almost the same.

one of these carrier shows FACH congestion.

- RTWP ok (the same)
- ECNO the same
- Parameter check ok (the same setting)

What could be the reason ?

giegala
2014-12-10, 11:46 PM
Hi,

probably it is reselection parameters.

fahmi
2015-01-05, 08:13 PM
Hi,

probably it is reselection parameters.

Dear giegala,

Absolutely right, it was due to reselection parameters that push traffic to congested cell.

BR,
Fahmi

jeff
2015-01-06, 02:12 AM
Hi Fahmi,
Please share those parameters and their values before and after changes


Dear giegala,

Absolutely right, it was due to reselection parameters that push traffic to congested cell.

BR,
Fahmi

fahmi
2015-01-07, 05:02 PM
Hi Fahmi,
Please share those parameters and their values before and after changes

Dear,





OLD
NEW


S-CI
N-CI
IdleQoffset1sn
IdleQoffset2sn
IdleQoffset1sn
IdleQoffset2sn


18832
18837
4
4
0
0


18837
18832
-4
-4
0