PDA

View Full Version : Question 3G E******* Hardware activation code for HS Max codes in RBS



Muhammad Imran Rafique
2014-12-08, 01:47 AM
Hi Experts
Can any one share/confirm, do we have any limitation i.e. Hardware activation code for "max HS Codes" per cell or sector or DUW.

Example:
i.e. DUW30 can support up to 1024 CE UL however if hardware activation code is not allowed up to this limit, simply we cant use 1024 completely in UL.

looking for urgent support, please share.

BR//
Imran

electron
2014-12-08, 02:15 AM
Hi Experts
Can any one share/confirm, do we have any limitation i.e. Hardware activation code for "max HS Codes" per cell or sector or DUW.

Example:
i.e. DUW30 can support up to 1024 CE UL however if hardware activation code is not allowed up to this limit, simply we cant use 1024 completely in UL.

looking for urgent support, please share.

BR//
Imran

Hi,

Yes there is , In DUW there is limitation of simultaneous code assignment per sector/carrier. That's why E/// introduced optional feature "Increased HS code for DUW".


Cheers

Muhammad Imran Rafique
2014-12-08, 02:44 PM
Dear Electron,

I will really appreciate if you can share exact parameters to confirm what are our current limitations.

Regards,
Imran

ericsson.technoz
2014-12-08, 08:44 PM
I think You can check this parameter numhscoderesources.May be it will be helpful.

electron
2014-12-09, 02:26 PM
Dear Electron,

I will really appreciate if you can share exact parameters to confirm what are our current limitations.

Regards,
Imran

Hi Imran,

Use "get . featureStateIncreasedHsCodeCap" in RBS.

Cheers

Muhammad Imran Rafique
2014-12-09, 08:21 PM
i can confirm now everyone, the hardware activation code limit is valid and is visible in RBS inventory

invl

this is the first limit, any feature can just re-distribute codes among different cells and carriers. But real limit exist here.

hope everyone is now clear.

BR//
Imran