PDA

View Full Version : Question How to check missing Neighbors from M2000



theoptimizer
2014-10-12, 04:28 AM
Hi Experts,

Can someone share if there is a way to get missing Neighbors/Detected set from measurements in M2000. We dont have Nastar or PRS but i have OMSTAR but i couldn't find the option there as well

Thanks

P.T.E.
2014-10-12, 08:14 AM
Dear,

Using OMStar u can check performance logs and check SHO.

captain_jejemon
2014-10-12, 01:28 PM
Hi, this is for 2G or 3G or LTE? you can check the cell to cell handover commands and success.
there are counters you can check

theoptimizer
2014-10-13, 04:43 AM
Its for UMTS. I know per Neighbors Counters what i am interested in is missing Neighbors/Detected Neighbors from Measurement. I used to do this in past using Nastar but now we only have access to M2000.

theoptimizer
2014-10-13, 04:58 AM
I need to Check detected Neighbors not Per Neighbor relation Attempts/Success. Again we only have access to M2000 and OMSTAR

P.T.E.
2014-10-14, 05:20 AM
if im not wrong you can check the SHO failures then check if the 2 cells that have high SHO failures are defined as NBs.

qaqa
2014-10-14, 06:19 AM
Hello,

enable the NCELL counters. than if you have the HO_INTRA_FREQ_DETSET_INTO_ACTSET_SWITCH switch enabled under UCORRMALGOSWITCH enabled, the Detected cell could be added to active set and the counter will peg for it. With your cell neighbour configuration, you can export form M2000 or through OMStar you can easily detect the missing neighbours.
no if you want to improve you KPIs even though with missing neighbours I have the following suggestions:
1- enable the switch above and the Neighbour combining as well under the same table.
2- enable call re-establishment for CS and PS (CHeck HedeX for details).

nron3
2014-10-21, 08:57 PM
mostly we will check the counter from omstar.....

tharinduwije
2014-10-22, 05:43 PM
Hi ,

Do you have the specific counters & method of exporting the Active set data? How does the M2000 recognize whether its active set or detected?

theoptimizer
2014-10-23, 12:44 AM
Hi ,

Its working now you have to enable the 2 switch in UCORRMA regrading detected set and than from Per cell 3G and 3G-2G Per Neighbor stats you can find missing Neighbors Thanks

qaqa
2014-10-23, 07:31 AM
good to hear it worked for you :-)

tharinduwije
2014-10-23, 10:12 PM
Hi ,

Its working now you have to enable the 2 switch in UCORRMA regrading detected set and than from Per cell 3G and 3G-2G Per Neighbor stats you can find missing Neighbors Thanks

Hi,

Can you be specific of the counters you used? Will these do the trick?



VS.HHO.AttInterFreqIn
VS.HHO.AttInterFreqOut
VS.HHO.SuccInterFreqIn
VS.HHO.SuccInterFreqOut




VS.SHO.AS.3RL
VS.SHO.AS.4RL
VS.SHO.AS.5RL
VS.SHO.AS.6RL
VS.SHO.AttRLAdd
VS.SHO.AttRLAdd.Prep
VS.SHO.AttRLDel
VS.SHO.SuccRLAdd
VS.SHO.SuccRLDel
VS.SoHO.AttRLDel
VS.SoHO.AttRLAdd
VS.SoHO.SuccRLAdd
VS.SoHO.SuccRLDel

tharinduwije
2014-10-23, 10:26 PM
Or these counters,



VS.HHO.AttOut.NCell
VS.HHO.SuccOut.NCell
VS.SHO.AddRLAtt.NCell
VS.SHO.AddRLSucc.NCell
VS.SHO.SuccASU.NCell
VS.SHO.AttASU.NCell
VS.SHO.FailASU.NoReply.NCell

qaqa
2014-10-25, 01:57 PM
the NCELL counters

theoptimizer
2014-10-29, 08:17 PM
in M200 use Counters in following 2 reports

Measurements between cell and interRat Cell - for 3G-2G
Measurement between cell and a umts cell - for 3G-3G

Thanks

npo.david
2014-11-27, 06:00 AM
I saw 1 feature may relate: UautoNCellDetect but not yet tried :)

RF Engr
2014-12-15, 01:37 PM
in M200 use Counters in following 2 reports

Measurements between cell and interRat Cell - for 3G-2G
Measurement between cell and a umts cell - for 3G-3G

Thanks
Dear Friend,
Could you please provide counter names which shows detected neighbors for U-U and U-G?
Thanks in advance

AhmadE
2015-02-01, 10:05 PM
Dear theoptimizer (http://www.finetopix.com/member.php?2526-theoptimizer)

do you need to check the one way relation neighbors?
you can check it from CME from:
Advance-->Consistency Check --> then check on unidirectional neighbors.




Hi Experts,

Can someone share if there is a way to get missing Neighbors/Detected set from measurements in M2000. We dont have Nastar or PRS but i have OMSTAR but i couldn't find the option there as well

Thanks

samuraial
2015-02-02, 05:03 PM
This one opens the neighbor detect and add them at MR that you collect and import in Omstar or iManager Nastar.

For Intra frequency(UMTS) you can use:

VS.SHO.AddRLAtt.NCell
VS.SHO.AddRLSucc.NCell
VS.SHO.SuccASU.NCell
VS.SHO.AttASU.NCell

Make a list of existing neighbors and vlookup the values from the data you get from the counters above or open "MR" and check them with Omstar.

B/R