PDA

View Full Version : 3g intra frequency periodic measurement control format



pdk5
2014-05-22, 04:57 AM
Dear friends,

I am looking for the template for the "3g intrafrequency Measurement control" to trigger periodic measurements.

I had tried to send the following message to trigger this. But i am getting back measurement report from the UE, but the cell list containing the measurements in empty.

DL-DCCH-Message
integrityCheckInfo
messageAuthenticationCode: 149a6f37 [bit length 32, 0001 0100 1001 1010 0110 1111 0011 0111 decimal value 345665335]
rrc-MessageSequenceNumber: 3
message: measurementControl (8)
measurementControl: later-than-r3 (1)
later-than-r3
rrc-TransactionIdentifier: 1
criticalExtensions: r4 (0)
r4
measurementControl-r4
measurementIdentity: 7
measurementCommand: setup (0)
setup: intraFrequencyMeasurement (0)
intraFrequencyMeasurement
intraFreqCellInfoList
removedIntraFreqCellList: removeAllIntraFreqCells (0)
removeAllIntraFreqCells: NULL
newIntraFreqCellList: 2 items
Item 0
NewIntraFreqCell-r4
intraFreqCellID: 0
cellInfo
modeSpecificInfo: fdd (0)
fdd
primaryCPICH-Info
primaryScramblingCode: 124
.... ..0. readSFN-Indicator: False
.... ...0 tx-DiversityIndicator: False
Item 1
NewIntraFreqCell-r4
intraFreqCellID: 1
cellInfo
modeSpecificInfo: fdd (0)
fdd
primaryCPICH-Info
primaryScramblingCode: 202
.... 0... readSFN-Indicator: False
.... .0.. tx-DiversityIndicator: False
intraFreqMeasQuantity
modeSpecificInfo: fdd (0)
fdd
intraFreqMeasQuantity-FDD: cpich-Ec-N0 (0)
intraFreqReportingQuantity
activeSetReportingQuantities
dummy: noReport (0)
.... .0.. cellIdentity-reportingIndicator: False
.... ..0. cellSynchronisationInfoReportingIndicator: False
modeSpecificInfo: fdd (0)
fdd
1... .... cpich-Ec-N0-reportingIndicator: True
.1.. .... cpich-RSCP-reportingIndicator: True
..0. .... pathloss-reportingIndicator: False
monitoredSetReportingQuantities
dummy: noReport (0)
.... .0.. cellIdentity-reportingIndicator: False
.... ..0. cellSynchronisationInfoReportingIndicator: False
modeSpecificInfo: fdd (0)
fdd
1... .... cpich-Ec-N0-reportingIndicator: True
.1.. .... cpich-RSCP-reportingIndicator: True
..0. .... pathloss-reportingIndicator: False
reportCriteria: periodicalReportingCriteria (1)
periodicalReportingCriteria
periodicalReportingCriteria
reportingInterval: ril2 (4)
measurementReportingMode
measurementReportTransferMode: acknowledgedModeRLC (0)
periodicalOrEventTrigger: periodical (0)
v4d0NonCriticalExtensions
v590NonCriticalExtensions
measurementControl-v590ext
rrc-TransactionIdentifier-MSP-v590ext: 0



thanks
pdk

pdk5
2014-05-22, 03:22 PM
Friends, could you please reply to the this please. I have not been working on measurments. So it might be very simple mistake in Measurement control to trigger the periodc measurements. I guess some of you must have some kind of testing and there may be some logs, could you please send a template for the same.

thanks a lot in advance for the replies :)

pdk5
2014-05-22, 10:02 PM
Now found a template in the 34.123 section TC number 8.4.1.5 . My MC seems like this, but still UE sending Measurement Report with the number of cells = 0. May be it is some other params i.e missing in the MC !