Hi,
I have observed a strange case where UE is receiving BCCH system information after active set update complete during a voice call. This is happening frequently after active cell update complete (but not all the time) with Huawei P1 handset. UE data was turned off during DT. The time-stamps show BCCH info being received from ~1s to ~5s and the voice call continues normally despite such gaps of no measurement reports in UL and call control signaling in DL. Any ideas what might be the reason ?
35275
I have observed a strange case where UE is receiving BCCH system information after active set update complete during a voice call. This is happening frequently after active cell update complete (but not all the time) with Huawei P1 handset. UE data was turned off during DT. The time-stamps show BCCH info being received from ~1s to ~5s and the voice call continues normally despite such gaps of no measurement reports in UL and call control signaling in DL. Any ideas what might be the reason ?
35275