dear Pl. find the parameter below tuned for HO and PS power control. these settings gave us tremendous improvement. we have implemented across whole network after testing. (release R14. Ps power control is optional feature)
CS
Parameter name
Running
Required
MML
BQ Margin
69
65
G2GNCells (All NCEll)
PWRC
YES
NO
GCELLCCCH
TCHH Allocation Considering Signal Level
off
on
Gcellchmgad
MinRxLevWhenAssignHr
15
23
Gcellchmgad
Enhanced TCH Adjust Allowed
YES
NO
GCELLCHMGBASIC
Min UL Level on Candidate Cell
10
12
GCELLHO BASIC
Min DL Level on Candidate Cell
15
20
GCELLHO BASIC
Min interval for TCH HO
5
2
GCELLHOCTRL
Min Interval for Consecutive HOs
5
0
GCELLHOCTRL
Filter Length for Ncell RX_LEV
4
5
GCELLHOFITPEN
Filter Length for TCH Level
4
5
GCELLHOFITPEN
Filter Length for TCH Qual
4
5
GCELLHOFITPEN
Power Control and Handover CMP CON Sw
NO
YES
GCELLOTHEXT
ULFSRexQualHighThred
16
14
GCELLPWR3
ULFSRexQualLowThred
16
14
GCELLPWR3
ULHSRexQualHighThred
16
14
GCELLPWR3
ULHSRexQualLowThred
16
14
GCELLPWR3
ULAFSRexQualHighThred
16
14
GCELLPWR3
ULAFSRexQualLowThred
16
14
GCELLPWR3
ULAHSRexQualHighThred
16
14
GCELLPWR3
ULAHSRexQualLowThred
16
14
GCELLPWR3
DLFSRexQualHighThred
16
16
GCELLPWR3
DLFSRexQualLowThred
16
16
GCELLPWR3
DLHSRexQualHighThred
16
16
GCELLPWR3
DLHSRexQualLowThred
16
16
GCELLPWR3
DLAFSRexQualHighThred
16
16
GCELLPWR3
DLAFSRexQualLowThred
16
16
GCELLPWR3
DLAHSRexQualHighThred
16
16
GCELLPWR3
DLAHSRexQualLowThred
16
16
GCELLPWR3
DLRexLevSlideWindow
1
2
GCELLPWR3
DLRexQualSlideWindow
1
2
GCELLPWR3
ULRexLevSlideWindow
1
1
GCELLPWR3
ULRexQualSlideWindow
1
1
GCELLPWR3
ULRexLevExponentFilterLen
3
3
GCELLPWR3
DLRexLevExponentFilterLen
6
3
GCELLPWR3
III DL RexLev Protect Factor
15
7
GCELLPWR3
III UL RexLev Protect Factor
15
7
GCELLPWR3
DLRexLevHighThred
25
17
GCELLPWR3
DLRexLevLowthred
25
17
GCELLPWR3
ULRexLevHighThred
15
7
GCELLPWR3
ULRexLevLowThred
15
7
GCELLPWR3
PwrCtrlULAdjPeriod
3
1
GCELLPWR3
PwrCtrlDLAdjPeriod
2
1
GCELLPWR3
Dynamic PDCH Apply Interval when CS Busy
0
30
GCELLPSCHM
PS
MOP for DTX power control
Active downlink PS DTX command:
SET GCELLPRIVATEOPTPARA: IDTYPE=BYID, CELLID=0, PSDTX=ENHANCEDDTX;
SET GCELLPSOTHERPARA: IDTYPE=BYID, CELLID=0, DlPACKSENDPERIOD=5;
Active uplink PS DTX command:
SET GCELLPSBASE: IDTYPE=BYID, CELLID=0, EXTUTBFNODATA=NOTSEND, INACTSCHPERIOD=5;
PS power control parameter value:
Parameter ID
suggest value
MCSSTATTHR
1
MCSSTABTHR
1
DLPCSTARTTHR
MCS9
DLPCINITPR
DB6
TGTCIRPOS
2
TGTCIROFFSET
0
MAXPCSTEP
15
PSPCPRES
0.6dB
DummyPRGran
15
USFDummyPCFactor
5
PSPCPOLICY
0
SUPEGPRSDLPCMROPT
Yes
EGPRSDLMRFLTGENE
10
MCSSTATTHR
1
MCSSTABTHR
1
GPRSDLPCSTARTTHR
CS4
DLPCINITPR
DB6
MAXPCSTEP
15
PSPCPRES
0.6dB
DummyPRGran
15
USFDummyPCFactor
5
GPRSDLMRFLTGENE
30
GPRSDLPCRELTHR
40
GPRSDLPCRELADJGENE
6
CS
Parameter name
Running
Required
MML
BQ Margin
69
65
G2GNCells (All NCEll)
PWRC
YES
NO
GCELLCCCH
TCHH Allocation Considering Signal Level
off
on
Gcellchmgad
MinRxLevWhenAssignHr
15
23
Gcellchmgad
Enhanced TCH Adjust Allowed
YES
NO
GCELLCHMGBASIC
Min UL Level on Candidate Cell
10
12
GCELLHO BASIC
Min DL Level on Candidate Cell
15
20
GCELLHO BASIC
Min interval for TCH HO
5
2
GCELLHOCTRL
Min Interval for Consecutive HOs
5
0
GCELLHOCTRL
Filter Length for Ncell RX_LEV
4
5
GCELLHOFITPEN
Filter Length for TCH Level
4
5
GCELLHOFITPEN
Filter Length for TCH Qual
4
5
GCELLHOFITPEN
Power Control and Handover CMP CON Sw
NO
YES
GCELLOTHEXT
ULFSRexQualHighThred
16
14
GCELLPWR3
ULFSRexQualLowThred
16
14
GCELLPWR3
ULHSRexQualHighThred
16
14
GCELLPWR3
ULHSRexQualLowThred
16
14
GCELLPWR3
ULAFSRexQualHighThred
16
14
GCELLPWR3
ULAFSRexQualLowThred
16
14
GCELLPWR3
ULAHSRexQualHighThred
16
14
GCELLPWR3
ULAHSRexQualLowThred
16
14
GCELLPWR3
DLFSRexQualHighThred
16
16
GCELLPWR3
DLFSRexQualLowThred
16
16
GCELLPWR3
DLHSRexQualHighThred
16
16
GCELLPWR3
DLHSRexQualLowThred
16
16
GCELLPWR3
DLAFSRexQualHighThred
16
16
GCELLPWR3
DLAFSRexQualLowThred
16
16
GCELLPWR3
DLAHSRexQualHighThred
16
16
GCELLPWR3
DLAHSRexQualLowThred
16
16
GCELLPWR3
DLRexLevSlideWindow
1
2
GCELLPWR3
DLRexQualSlideWindow
1
2
GCELLPWR3
ULRexLevSlideWindow
1
1
GCELLPWR3
ULRexQualSlideWindow
1
1
GCELLPWR3
ULRexLevExponentFilterLen
3
3
GCELLPWR3
DLRexLevExponentFilterLen
6
3
GCELLPWR3
III DL RexLev Protect Factor
15
7
GCELLPWR3
III UL RexLev Protect Factor
15
7
GCELLPWR3
DLRexLevHighThred
25
17
GCELLPWR3
DLRexLevLowthred
25
17
GCELLPWR3
ULRexLevHighThred
15
7
GCELLPWR3
ULRexLevLowThred
15
7
GCELLPWR3
PwrCtrlULAdjPeriod
3
1
GCELLPWR3
PwrCtrlDLAdjPeriod
2
1
GCELLPWR3
Dynamic PDCH Apply Interval when CS Busy
0
30
GCELLPSCHM
PS
MOP for DTX power control
Active downlink PS DTX command:
SET GCELLPRIVATEOPTPARA: IDTYPE=BYID, CELLID=0, PSDTX=ENHANCEDDTX;
SET GCELLPSOTHERPARA: IDTYPE=BYID, CELLID=0, DlPACKSENDPERIOD=5;
Active uplink PS DTX command:
SET GCELLPSBASE: IDTYPE=BYID, CELLID=0, EXTUTBFNODATA=NOTSEND, INACTSCHPERIOD=5;
PS power control parameter value:
Parameter ID
suggest value
MCSSTATTHR
1
MCSSTABTHR
1
DLPCSTARTTHR
MCS9
DLPCINITPR
DB6
TGTCIRPOS
2
TGTCIROFFSET
0
MAXPCSTEP
15
PSPCPRES
0.6dB
DummyPRGran
15
USFDummyPCFactor
5
PSPCPOLICY
0
SUPEGPRSDLPCMROPT
Yes
EGPRSDLMRFLTGENE
10
MCSSTATTHR
1
MCSSTABTHR
1
GPRSDLPCSTARTTHR
CS4
DLPCINITPR
DB6
MAXPCSTEP
15
PSPCPRES
0.6dB
DummyPRGran
15
USFDummyPCFactor
5
GPRSDLMRFLTGENE
30
GPRSDLPCRELTHR
40
GPRSDLPCRELADJGENE
6