PDA

View Full Version : Download 2G PS power control Parameter tuning



auto_art
2014-02-14, 02:11 PM
dear Pl. find the parameter below tuned for HO and PS power control. these settings gave us tremendous improvement. we have implemented across whole network after testing. (release R14. Ps power control is optional feature)

CS


Parameter name
Running
Required
MML


BQ Margin
69
65
G2GNCells (All NCEll)


PWRC
YES
NO
GCELLCCCH


TCHH Allocation Considering Signal Level
off
on
Gcellchmgad


MinRxLevWhenAssignHr
15
23
Gcellchmgad


Enhanced TCH Adjust Allowed
YES
NO
GCELLCHMGBASIC


Min UL Level on Candidate Cell
10
12
GCELLHO BASIC


Min DL Level on Candidate Cell
15
20
GCELLHO BASIC


Min interval for TCH HO
5
2
GCELLHOCTRL


Min Interval for Consecutive HOs
5
0
GCELLHOCTRL


Filter Length for Ncell RX_LEV
4
5
GCELLHOFITPEN


Filter Length for TCH Level
4
5
GCELLHOFITPEN


Filter Length for TCH Qual
4
5
GCELLHOFITPEN


Power Control and Handover CMP CON Sw
NO
YES
GCELLOTHEXT


ULFSRexQualHighThred
16
14
GCELLPWR3


ULFSRexQualLowThred
16
14
GCELLPWR3


ULHSRexQualHighThred
16
14
GCELLPWR3


ULHSRexQualLowThred
16
14
GCELLPWR3


ULAFSRexQualHighThred
16
14
GCELLPWR3


ULAFSRexQualLowThred
16
14
GCELLPWR3


ULAHSRexQualHighThred
16
14
GCELLPWR3


ULAHSRexQualLowThred
16
14
GCELLPWR3


DLFSRexQualHighThred
16
16
GCELLPWR3


DLFSRexQualLowThred
16
16
GCELLPWR3


DLHSRexQualHighThred
16
16
GCELLPWR3


DLHSRexQualLowThred
16
16
GCELLPWR3


DLAFSRexQualHighThred
16
16
GCELLPWR3


DLAFSRexQualLowThred
16
16
GCELLPWR3


DLAHSRexQualHighThred
16
16
GCELLPWR3


DLAHSRexQualLowThred
16
16
GCELLPWR3


DLRexLevSlideWindow
1
2
GCELLPWR3


DLRexQualSlideWindow
1
2
GCELLPWR3


ULRexLevSlideWindow
1
1
GCELLPWR3


ULRexQualSlideWindow
1
1
GCELLPWR3


ULRexLevExponentFilterLen
3
3
GCELLPWR3


DLRexLevExponentFilterLen
6
3
GCELLPWR3


III DL RexLev Protect Factor
15
7
GCELLPWR3


III UL RexLev Protect Factor
15
7
GCELLPWR3


DLRexLevHighThred
25
17
GCELLPWR3


DLRexLevLowthred
25
17
GCELLPWR3


ULRexLevHighThred
15
7
GCELLPWR3


ULRexLevLowThred
15
7
GCELLPWR3


PwrCtrlULAdjPeriod
3
1
GCELLPWR3


PwrCtrlDLAdjPeriod
2
1
GCELLPWR3


Dynamic PDCH Apply Interval when CS Busy
0
30
GCELLPSCHM





PS
MOP for DTX power control

Active downlink PS DTX command:

SET GCELLPRIVATEOPTPARA: IDTYPE=BYID, CELLID=0, PSDTX=ENHANCEDDTX;
SET GCELLPSOTHERPARA: IDTYPE=BYID, CELLID=0, DlPACKSENDPERIOD=5;

Active uplink PS DTX command:

SET GCELLPSBASE: IDTYPE=BYID, CELLID=0, EXTUTBFNODATA=NOTSEND, INACTSCHPERIOD=5;


PS power control parameter value:


Parameter ID
suggest value


MCSSTATTHR
1


MCSSTABTHR
1


DLPCSTARTTHR
MCS9


DLPCINITPR
DB6


TGTCIRPOS
2


TGTCIROFFSET
0


MAXPCSTEP
15


PSPCPRES
0.6dB


DummyPRGran
15


USFDummyPCFactor
5


PSPCPOLICY
0


SUPEGPRSDLPCMROPT
Yes


EGPRSDLMRFLTGENE
10


MCSSTATTHR
1


MCSSTABTHR
1


GPRSDLPCSTARTTHR
CS4


DLPCINITPR
DB6


MAXPCSTEP
15


PSPCPRES
0.6dB


DummyPRGran
15


USFDummyPCFactor
5


GPRSDLMRFLTGENE
30


GPRSDLPCRELTHR
40


GPRSDLPCRELADJGENE
6

RF engineer
2014-02-14, 04:19 PM
Dear

They are mostly power control related to voice only one I see is PS , it is possible to share the result as Iam doing power for DL PS for EGPRS just improved RX quality.

BR

electron
2014-02-14, 05:07 PM
Hi,


I tried it by myself. It is giving very negligible result in RxQual improvement. In my opinion do not spend your time on it .


Cheers
Dear

They are mostly power control related to voice only one I see is PS , it is possible to share the result as Iam doing power for DL PS for EGPRS just improved RX quality.

BR

auto_art
2014-02-14, 05:46 PM
if i share the results u mite change your mind to re-implement..
things to remember here 2G Ps power control means closed loop powr control not the stone age UL open loop.:)

auto_art
2014-02-14, 05:56 PM
POST AFP:PS DTX & PS PWR CTRL & CS Optimization Results:-

this is one prominent BSC highly utilized.

Ø HOSR NBH Improved from 98.04 to 98.61 avg & BAD Cell Count HOSR<95% decreased from 88 to 49 avg
Ø DL RX Quality(0-5)% Improved from97.01to 98.34 avg & BAD Cell Count DL RX Qual<95% decreased from 204 to 55 avg
Ø TCH DCR NBH Improved from .36 to .35 avg & BAD Cell Count <95% decreased from 20 to 15 avg
Ø TASR NBH improved from99.11to 99.16 avg & BAD Cell Count <95% decreased from 25 to17 avg

electron
2014-02-14, 06:59 PM
Hi,

yes mate , share your result i may change my opinion. I am aware about UL and DL power control :)

DL PS power control in E/// introduced since release G12 around 1.5 year ago . Will be waiting your complete report in regard.


Cheers
if i share the results u mite change your mind to re-implement..
things to remember here 2G Ps power control means closed loop powr control not the stone age UL open loop.:)

fannakhosr
2014-02-15, 08:57 PM
could you please elaborate more on parameter name as I search in alex g12 and 11B, but not find those parameters in the library

auto_art
2014-02-17, 09:24 PM
dear this is for Huawei

electron
2014-02-17, 10:10 PM
I am really in doubt about HOSR 98.04 to 98.61 improvement. If you have chance please share benchmark result of KPIs. Then it will be more clear.


Cheers
dear this is for Huawei

auto_art
2014-02-18, 07:24 PM
do you need pre post KPI trending.?

electron
2014-02-18, 07:42 PM
Hi,

In case if you have complete benchmark it will help to understand better.


Cheers
do you need pre post KPI trending.?