PDA

View Full Version : RU 30 with subunit KPI



ttngoc85
2013-07-19, 11:55 AM
With RU 30 NSN, We need upgrade software for node B to Release 7.0.2 to enable M5008Cx including subunit KPI like this picture.
Without this software, there's nothing in counters M5008Cx.
You can check these counters and KPI by go to NSN RU30 Report=>Capacity=>RSRAN131 Node B Utilization.
Hope this help

dtvt2
2013-07-19, 02:08 PM
Hi friend
- In my system. Node B use software version: 7.0.1. there are all subunit KPI in counter group M5008. You just enable it

ttngoc85
2013-07-20, 04:04 PM
Hi dtvt2,
It's so strange, becasue according to NED as attached picture. it says that these KPI only used from R7.0.2.
Maybe your system already use node B software 7.0.2.
BRs,

djordjebeg
2013-07-25, 09:12 PM
Hello colleges,


I can confirm they are used from WN7.01 as well.
But just a comment that accuracy was not good.
from WN7.02.2. bugs are corrected.
problem was with calculation of max hsupa throughput and number of available SUs.
BUT even in WN7022 there is problem with total hsupa load calculation as counters shows higher than it shell be based on dimensioning guideline.