Dear Gurus,
UL CE start appearing with 2nd carrier activation on 4 sector site however F1 is normal
There are two DUW30 boards configured with following
AvailableRbsChannelElements for DL and UL is 1024 and licensecapacityChannelelementsul=208
My question is licensecapacityChannelElementUl=208 is per board or total with two boards? and UL CE Usage with introduction of second carrier+2nd DUW30 should have decreased but it increases only on F2. Could it be because of wrong DUW30 board configuration settings, please help
Second, is there any role of basebandpool2 for above mentioned case. Current setting of ulLicFractBbPool2=50
Thanks.