PDA

View Full Version : NSN NodeB In Sync/Out Sync Parameters



Gauiver
2013-04-30, 03:42 AM
Hi,
Any one has any idea what is the parametere in NSN 3G for


N_INSYNC_IND (Number of In Sync Indications at the NodeB (Not UE!) to achieve uplink Synchronization)
N_OUTSYNC_IND (Number of out of Sync Indications at the NodeB (Not UE!))



Gauiver

hasan_gn
2013-05-02, 09:09 PM
Hi,

Regarding the parameters which you are looking for, in fact these are hardcoded values. You can find them in IUB trace in NBAP:Cell Setup message.
Anyway the values of these parameters are fixed and set as following:
T_RLFAILURE: default value = 2 second
N_OUTSYNC_IND: default value = 8
N_INSYNC_IND: default value =

giegala
2013-05-10, 05:50 PM
can you please add value for N_INSYNC_IND

thanks

nupong
2013-06-11, 05:01 PM
For Huawei, these parameters are not fixed
Default:
NInsyncInd = 5
NOutsyncInd = 50
TRLFailure = 50

SHIVAM
2013-06-12, 02:24 AM
hi giegala,

The value for N_INSYNC_IND is 8 for nsn system.