2013-01-09, 12:10 PM
Hi Mates,

Any ideas on how to solve high SD drop mainly due to RF fail?Problem only occurred in one sector.
Freq,TA, and Par were ok and no HW alarm.
NSN equipment...
Thanks...

Ryurikovich
2013-01-09, 03:35 PM
That is software malfunction supposedly. Try to reset the BTS.

ashraferto
2013-01-13, 02:30 PM
Agree with you, Reset solve most of TCH and SD Drop in NSN, also its better to check the TCSM alarms.


That is software malfunction supposedly. Try to reset the BTS.

ventinel
2013-02-15, 03:39 PM
Check and change the value of timer T200

Hi Mates,

Any ideas on how to solve high SD drop mainly due to RF fail?Problem only occurred in one sector.
Freq,TA, and Par were ok and no HW alarm.
NSN equipment...
Thanks...

sabila
2013-02-22, 10:06 PM
Check for trx quality and level
Scanctrx
May be degraded hardware without alarm