rachatak
2012-09-14, 08:39 PM
Now i set parameter in cell level :
MSC Version Indication = R99 or above
Measurement Report Type = Common Measurement Report
Serving Band Reporting = 3
Qsearch I = 7
Qsearch C Initial = Use Qsearch_I
FDD Q Offset = 0
FDD RSCP Min. = 0
FDD REP QUANT = RSCP
FDD Multirate Reporting = 2
FDD Qmin = 7
FDD Qmin Offset = 0
Qsearch P = 7
3G Search PRIO = Yes
Invalid BSIC Reporting = No
SCALE_ORDER = +0dB
Qsearch C = 15
900 Reporting Offset = 0
900 Reporting Threshold = 0
1800 Reporting Offset = 0
1800 Reporting Threshold = 0
FDD Reporting Offset = 0
FDD Reporting Threshold = 0
TDD Cell Reselect Diversity = 8
Best TDD Cell Number = 1
TDD Reporting Offset = 0
TDD Reporting Threshold = 0
TDD System Information Optimized Allowed = No
TDD MI System INFO Broadcasting Prohibit = No
TDD MI System Information Optimized = No
2Quater Message Transmission Channel = BCCHNorm
(Number of results = 1)
Please suggest me if have other parameter
MSC Version Indication = R99 or above
Measurement Report Type = Common Measurement Report
Serving Band Reporting = 3
Qsearch I = 7
Qsearch C Initial = Use Qsearch_I
FDD Q Offset = 0
FDD RSCP Min. = 0
FDD REP QUANT = RSCP
FDD Multirate Reporting = 2
FDD Qmin = 7
FDD Qmin Offset = 0
Qsearch P = 7
3G Search PRIO = Yes
Invalid BSIC Reporting = No
SCALE_ORDER = +0dB
Qsearch C = 15
900 Reporting Offset = 0
900 Reporting Threshold = 0
1800 Reporting Offset = 0
1800 Reporting Threshold = 0
FDD Reporting Offset = 0
FDD Reporting Threshold = 0
TDD Cell Reselect Diversity = 8
Best TDD Cell Number = 1
TDD Reporting Offset = 0
TDD Reporting Threshold = 0
TDD System Information Optimized Allowed = No
TDD MI System INFO Broadcasting Prohibit = No
TDD MI System Information Optimized = No
2Quater Message Transmission Channel = BCCHNorm
(Number of results = 1)
Please suggest me if have other parameter