View Full Version : Fingerprint
prem19809
2012-07-02, 11:53 PM
Hi friends,
Please can you confirm, after changing DUW Is it fingerprint will changes in Node B or it will be remain the same?
Rgds,
prem
Abuelooorl
2012-07-03, 03:34 AM
Hi.
Fingerprint changes.
You must connect all cables in the same position BEFORE powering the DUW on to keep the hardware fingerprint.
BR.
jamal
2012-07-03, 12:57 PM
Hi Mate,
It will remain same. Since, fingerprint on RBS 6000, not stored only in DUW but in RUW/RUS also. So connect all cables then power up the DUW.
hope help.
BR//
prem19809
2012-07-03, 03:04 PM
Hi Jamal,
Thank you for your replay and my Node B type is 6601, DUW with MU. Fingerprint will consider/stored in MU or DUW?
Rgds,
prem
prem19809
2012-07-03, 03:45 PM
Hi Friend,
Thank you for your replay and my Node B type is 6601, DUW with MU. Fingerprint will consider/stored in MU or DUW?
Rgds,
prem
sabila
2012-07-05, 10:37 AM
check your fingerprint with CABX command from moshell
compare before and after replacement
rmtelecom
2012-07-12, 03:10 AM
Hi, the MO to check is Licensing=1, usualy just do "get 6" in moshell to check your fingerprint.
BR
jamal
2012-07-12, 01:17 PM
Hi Jamal,
Thank you for your replay and my Node B type is 6601, DUW with MU. Fingerprint will consider/stored in MU or DUW?
Rgds,
prem
Hi Prem,
Basically E******* RBS 6000 series is the same. So, if You replace the DUW in your MU, then your fingerprint still stored on RRUW/S
CMIIW,
BR.
prem19809
2012-07-13, 10:56 PM
Thank you Jamal.
Rgds,
Prem