PDA

View Full Version : 3G Call setup failure in Drive test



ozgurzcn
2012-06-13, 04:48 PM
Hi Experts,

I have call setup failure problem in my 3G network during the drive test.

Radio situation is OK (EcIo =-5-6 RSCP=-60-65)
After RAB setup complete message CC disconnect message is coming
in Layer 3 message, failure cause= resource unavailable

27987


Vendor is NSN RU20
Thank you in advance for your help

ninjafine
2012-06-14, 04:01 AM
Hi Experts,

I have call setup failure problem in my 3G network during the drive test.

Radio situation is OK (EcIo =-5-6 RSCP=-60-65)
After RAB setup complete message CC disconnect message is coming
in Layer 3 message, failure cause= resource unavailable

27987



Vendor is NSN RU20
Thank you in advance for your help


Hi! What is the IE "Location" for CC Disconnect? Does CC Release have the same cause?
What is the number you are calling? Is it mobile from you network?
Seems you have problem at Core Network.
Please check related KPI's such as Drop RRC %, CS signaling SR%, number of System Nas signaling Release Cs.


Thanks and reps are appreciated.

ozgurzcn
2012-06-19, 01:04 PM
Thank you Dude,

We solve, it is due to test number.