PDA

View Full Version : Original RRC Measurements in UMTS



nemjain
2012-03-26, 04:55 PM
RRC measurement events
All measurement events are described in 3GPP TS 25.331
INTRA-FREQUENCY EVENTS


Event 1a

A Primary CPICH enters the Reporting Range (FDD only).



Event 1b

A Primary CPICH leaves the Reporting Range (FDD only).



Event 1c

A Non-active Primary CPICH becomes better than an active Primary CPICH (FDD only).



Event 1d

Change of best cell (FDD only).



Event 1e

A Primary CPICH becomes better than an absolute threshold (FDD only).



Event 1f

A Primary CPICH becomes worse than an absolute threshold (FDD only).




INTER-FREQUENCY EVENTS


Event 2a

Change of best frequency.



Event 2b

The estimated quality of the currently used frequency is below a certain threshold and the estimated quality of a non-used frequency is above a certain threshold.



Event 2c

The estimated quality of a non-used frequency is above a certain threshold.



Event 2d

The estimated quality of the currently used frequency is below a certain threshold.



Event 2e

The estimated quality of a non-used frequency is below a certain threshold.



Event 2f

The estimated quality of the currently used frequency is above a certain threshold.




INTER-RAT EVENTS


Event 3a

The estimated quality of the currently used UTRAN frequency is below a certain threshold and the estimated quality of the other system is above a certain threshold.



Event 3b

The estimated quality of other system is below a certain threshold.



Event 3c

The estimated quality of other system is above a certain threshold.



Event 3d

Change of best cell in other system




TRAFFIC VOLUME MEASUREMENT EVENTS


Event 4a

Transport Channel Traffic Volume becomes larger than an absolute threshold



Event 4b

Transport Channel Traffic Volume becomes smaller than an absolute threshold




QUALITY MEASUREMENT EVENTS


Event 5a

A predefined number of bad CRCs is exceeded




UE INTERNAL MEASUREMENT EVENTS


Event 6a

The UE Tx power becomes larger than an absolute threshold



Event 6b

The UE Tx power becomes less than an absolute threshold



Event 6c

The UE Tx power reaches its minimum value



Event 6d

The UE Tx power reaches its maximum value



Event 6e

The UE RSSI reaches the UE's dynamic receiver range



Event 6f (FDD)

The UE Rx-Tx time difference for a RL included in the active set becomes larger than an absolute threshold



Event 6g

The UE Rx-Tx time difference for a RL included in the active set becomes less than an absolute threshold




UE POSITIONING MEASUREMENT EVENTS


Event 7a

The UE position changes more than an absolute threshold



Event 7b

SFN-SFN measurement changes more than an absolute threshold



Event 7c

GPS time and SFN time have drifted apart more than an absolute threshold