PDA

View Full Version : Call Drop in OL subcell



BALKY
2011-12-13, 05:46 AM
Hi All,
is there anybody to know what can be the reasons for DL quality drop in OL subcell. The most of drops are in the OL and they are observe in whole BSC area.
Best regards,

tremalnike
2011-12-13, 06:40 AM
May be too high LOL, high LOL and high LOLYST or wrong FBOFFSET in case of DB Cell ? What's your parameter values ?

BALKY
2011-12-13, 07:14 AM
Hi tremalnike,
thank you for your answer... The values are LOL=121,LOLHYST=8 and FBOFFSET=7 for OLsubcell in Dualband cells..
BR,

BALKY
2011-12-13, 06:51 PM
Is there anybody idea for this problem?

Mr.David
2011-12-13, 07:27 PM
Bro,
You can try to adjust FBOFFSET to propper value and it work for some cases

tremalnike
2011-12-13, 10:05 PM
I think that the values are OK.
Check some cell for DCS crossed sectors.

BALKY
2011-12-14, 11:27 PM
HI tremalnike,
I think that the problems are not related to DCS crossed sector because we have problems in whole BSC areas, not only in one sector....
BR,

iara
2011-12-15, 11:41 AM
Hi tremalnike,
thank you for your answer... The values are LOL=121,LOLHYST=8 and FBOFFSET=7 for OLsubcell in Dualband cells..
BR,

try to reduce LOLHYST to 3

ventinel
2011-12-15, 01:23 PM
hi, can i know the vendor and hopping scheme used?

BALKY
2011-12-15, 04:37 PM
Hi all,
the problem is not in SFH, because we observe the same problem in cell that there is no SFH. The problem occurs and in 1800_micro cells, not just in Dualband cell..
BR,

BALKY
2011-12-19, 04:23 PM
Is there anybody idea for this problem?