PDA

View Full Version : Question How to change E-tilt



_lisi4king
2011-09-27, 03:02 AM
Good day, i need to change a lot of e-tilts some times per each day. How is it possible to do? Now we do it via MML, mannualy one by one, but does anyone know how to run it for 100 cells in one time for exapmle? I have MML and CME only, no special software.

:cool:

zaebolll
2011-09-27, 03:45 AM
Hello, if you do with MML, try to prepare an excel template with excel formulas

_lisi4king
2011-09-27, 02:51 PM
Hello, if you do with MML, try to prepare an excel template with excel formulas

But can you share example of this command? As i can see in command - it is not related with NodeB, only with RET. But if i have for all sites RET20, RET21,RET22 (as i remember), how do devide it that for RET20 (cell 10001) shold be 4 degree and for RET20 (cell 20003) should be 2? :confused:

pl_ev_7
2011-09-27, 03:01 PM
Mate,

You should be able to create a single file containing all the MML commands for your cells from Excel. Just get one of the MML commands a s text, write a concatenate in Excel for each cell you need to change the etilt, and then save the resulting column as a text file. In M2000 you a have an option to run a Batch MML.

I hope it helps. If not just reply and attach an excel file with the cells and tilts.

_lisi4king
2011-09-27, 08:31 PM
Yes, it is possible.

But when i run for some cells, i see notification "system busy". Will it change after some time ot not? Because as i can see - it doesn't change :(

pl_ev_7
2011-09-27, 10:16 PM
As I remember the tool, you could save the log of excuted commands.
If some of them didn't run in the first batch, create a second batch just for the ones with errors and run it again. Now the "system busy" error you should try to investigated first, maybe some of the boards are not working well, or the RET is not initialised.

_lisi4king
2011-09-27, 10:43 PM
As I remember the tool, you could save the log of excuted commands.
If some of them didn't run in the first batch, create a second batch just for the ones with errors and run it again. Now the "system busy" error you should try to investigated first, maybe some of the boards are not working well, or the RET is not initialised.

No, if i make it one by one it works good, but if i change 3 cells together, system change only first, for the rest - system busy :confused:

zaebolll
2011-09-28, 01:29 AM
Would like to help but i have not enough experince with Huawei on that issue, in NSN systems we also get sometimes system busy message but process continues after couple minutes.