View Full Version : How to determine if a EVDO site is congested



khalids
2011-06-28, 06:08 PM
Hello Dear colleagues, can anyone please tell how I can determine if an EVDO Rev A site is congested and in need of capacity upgrade.

All assistance will be appreciated.

Thanks in anticipation.

aosan
2011-06-28, 08:34 PM
Hello Dear colleagues, can anyone please tell how I can determine if an EVDO Rev A site is congested and in need of capacity upgrade.

All assistance will be appreciated.

Thanks in anticipation.

you can check the following:

1- Slot ocubancy ratio<=75%
2- Total active users (1 DOA carrier @300kbps/user should be <12 user)

khalids
2011-06-28, 08:52 PM
Thanks Aosan for the reply.

I got similar responses from some of my colleagues in the industry,
Some say,
1- Slot ocubancy ratio<=75%
2- Total active users (1 DOA carrier @300kbps/user should be <12 user)

1- Slot ocubancy ratio<=90%
2- Total active users (1 DOA carrier @300kbps/user should be <7 user)

1- Slot ocubancy ratio<=70%
2- Total active users (1 DOA carrier @300kbps/user should be <8 user)

Do you have any idea how the values are derived, what determines the number of user limit and the slot occupancy limit.

And is the analysis to be done based on Busy Hour Statistics.

Thanks in anticipation

da_manole
2011-06-29, 02:07 AM
depends on user activity(browsing or download movies)

T_ADD
2011-06-29, 07:16 AM
Thanks Aosan for the reply.

I got similar responses from some of my colleagues in the industry,
Some say,
1- Slot ocubancy ratio<=75%
2- Total active users (1 DOA carrier @300kbps/user should be <12 user)

1- Slot ocubancy ratio<=90%
2- Total active users (1 DOA carrier @300kbps/user should be <7 user)

1- Slot ocubancy ratio<=70%
2- Total active users (1 DOA carrier @300kbps/user should be <8 user)

Do you have any idea how the values are derived, what determines the number of user limit and the slot occupancy limit.

And is the analysis to be done based on Busy Hour Statistics.

Thanks in anticipation

It indeed is the Slot Occupancy Rate - greater than 75% or so needs either of the following.

optimise sector by downtilt etc if SOR is high on just one sector to distribute load better to near by sites if available.

add another EVDO CECM card, off course another frequency will be required.

add another BTS nearby to balance load.

you should also check minimum idle reverse CEs for that congesting BTS EVDO.

bengurion
2011-06-29, 11:17 AM
Hello Dear colleagues, can anyone please tell how I can determine if an EVDO Rev A site is congested and in need of capacity upgrade.

All assistance will be appreciated.

Thanks in anticipation.

to which vendor?

khalids
2011-06-29, 03:57 PM
I'm looking at Huawei Equipment.........Any more suggestions regarding EVDO congestion and what to look out for