PDA

View Full Version : Original Huawei ISStar m2000 Guidance



sabila
2011-03-08, 10:44 PM
Dear all,
here guidance for use isstar
to
1.create query alarm
2.create query performance
3.count trx
4.create potential data of bsc
etc ect


no pass :p

sabila
2011-03-08, 10:55 PM
example script to create sys info BTS

sabila
2011-03-08, 10:57 PM
example script to create sys info count trx

maahsan
2011-03-21, 06:21 PM
example script to create sys info count trx

File is password protected. Please post the password.

sabila
2011-03-21, 08:36 PM
sorry this file create before
i had default pass

fpr this file pass:f1netopix

maahsan
2011-03-21, 10:33 PM
Thanks, password working. Did you have scripts for BSC6900 as well.

sabila
2011-03-22, 12:17 AM
script for what kind colllect??

maahsan
2011-03-22, 02:42 AM
same BTS and TRX...do we need to just change LST TRX to LST GTRX.

gigel
2011-03-22, 04:37 AM
this software is kind of m2000 client or is working with some omc logs/traces?

maahsan
2011-03-22, 04:31 PM
You can execute scripts in iSStar so that you don't have to do repetiive tasks in M2000.

sabila
2011-03-24, 01:53 AM
@ mahsan
i think u can try to change lst trx to lst gtrx
sorry in my network just use bsc type 6000 :p



@gigel
in m2000 task schedule are limited in to minimal 1 hour for query(except performance)

if u need to query peridic to create configuration or grep alarm to show in database u will need this tool

diand
2011-03-24, 06:55 PM
Many thanks sabila (http://www.finetopix.com/members/sabila.html) for sharing these documents


Regards,

Dian Darmawan

rajmeena06
2011-04-28, 08:38 PM
Hi Dear,

Can u explain what we can do with isstar ,Here we have bsc6000.Pl explain

Gmundaez
2011-05-12, 09:55 AM
Hello Experts,

Could any one upload m2000 basic command list with descriptions.

Thanks.

f_tito
2011-05-12, 10:30 AM
Great.... THanks...

martinisonline
2011-07-11, 02:39 AM
Hello,

I'm writing a script to fetch from the DB all the records of a specific alarm.

From the documentation, i can see that to config the 'query' to retrieve only a specific alarm i have to configure the 'ALARMINFO_SEQ' with 3 parameters:
1.ProductId
2.NeTypeId
3.AlarmId.

The ProductId can be:
•1: transmission
•2: mobile
•3: fixed network narrowband
•4: fixed network wideband
•5: intelligent
•6: network management

The NeTypeId can be:
•100000: OMC
•1: RNC
•2: NodeB
•3: SGSN
•4: GGSN
•5: CG
•6: SoftX
•7: MGW
•8: HLR

The AlarmId is the id of the alarm i want to search!

If i want to get all the records of the alarm 21801 (GSM Cell out of Service)
from a BSC6900GSM what kind of of configuration i have to do?
The option of the NeTypeId dont have anything about BSC's!

BR,

sabila
2011-07-13, 05:33 PM
example
output MML like this

ALARM 586 Fault Critical BSC6000 21205 Software
Sync serial No. = 808
Alarm name = Board Fault
Alarm raised time = 2010-08-19 01:40:33
Location info = Subrack No.=0,Slot No.=15,Board Type=GF2/GOU/PEU, Alarm Attribute=Normal


u can used
5.5.20 Function: GetAlmID

then u will get 21205--->as alarm id