PDA

View Full Version : E******* handover parameters for cell



Tomas Delgado
2011-02-26, 04:32 AM
UeMeasControl parameter group controls handover in RNC. However i only find this group of commands once so i think this parameters are the same for all cells. How can i do to change this parameters for one particular cell?? thanks a lot

tsiz
2011-02-26, 05:25 AM
UeMeasControl parameter group controls handover in RNC. However i only find this group of commands once so i think this parameters are the same for all cells. How can i do to change this parameters for one particular cell?? thanks a lot

usedfreq2dRscp and usedfreq2dEcno
qqualmin and qexlevmin

Tomas Delgado
2011-02-26, 06:36 AM
Thanks mate, i found that ones in UtranCell, but lets say for example if i want to change event 1a threshold. I havent found this parameter for just one specific cell.

wolverine
2011-02-26, 07:42 AM
You cannot. These parameters are specified at the RNC level so cover all cells.

tsiz
2011-02-26, 01:49 PM
Thanks mate, i found that ones in UtranCell, but lets say for example if i want to change event 1a threshold. I havent found this parameter for just one specific cell.

yes..these are RNC specific parameters you are looking for and cannot be changed for a cell to cell basis.