PDA

View Full Version : Siemens BSS Counters DUMP DOCUMENT



choubeyb
2011-02-12, 02:00 AM
I need the document that will help me to decode & update database from the Siemens BSS Counter dump that is found in ASCII format. The File name starts with BR90 and has data like

Successful Internal Handovers per BSC per cause (0,0) Sun Jan 23 23:00:00+05:30 2011 bsc {21 0} {bss:21 bsc:0} 90 BSS:21/SCANBSC:0 60 1 0 0 0 306 2029 2679 854 0 5903 17 1083 1012 0 0 0 571 7516 12258 270 181 13133
Total number of Handover failures Intra BSC (0,14) Sun Jan 23 23:00:00+05:30 2011 bsc {21 0} {bss:21 bsc:0} 90 BSS:21/SCANBSC:0 60 1 0 0 0 357


I need to know the counter names. Eg in the line
BSS:21/SCANBSC:0 60 1 0 0 0 357
how to decode 0 is exactly what, 60 is what & so on.

Please help its urgent

m121
2011-02-12, 03:34 AM
Here you go:

SINHOBSC (0,0): successful internal handovers

Counter index:

1 Uplink quality
2 Downlink quality
3 Uplink strength
4 Downlink strength
5 Distance
6 Better cell (power budget related to the neighbor cell)
7 Directed retry
8 Inner to complete area (concentric cells)
9 Complete to inner area (concentric cells)
10 Near to far area (extended cells)
11 Far to near area (extended cells)
12 Traffic
13 Fast uplink
14 TCH/H to TCH/F due to AMR
15 TCH/F to TCH/H due to AMR
16 Compression handover from FR/EFR to HR
17 Decompression handover from HR to FR/EFR
18 Handover from TCH/WFS to TCH/NHS (compression handover; switch to
narrow band if TFO (tandem free operation) is not possible);
19 Handover from TCH/NHS to TCH/WFS (decompression handover);
20 Handover from TCH/WFS to TCH/AFS (robustness handover; switch to
narrow band if TFO (tandem free operation) is not possible);
21 Handover from TCH/AFS to TCH/WFS (homing handover)
22 Others

choubeyb
2011-02-13, 11:28 PM
Thanks, but i need the manual as i have the full dump of the BSC. I had pasted a sample as an example