PDA

View Full Version : Question Call Trace on Huawei RNC/M2000



salamanda1969
2010-10-13, 09:35 PM
Hello engineers,

Can someone provide guidelines or document on how to start a call trace in Huawei RNC or M2000 ? Many thanks.

slm

mirc84
2010-10-20, 02:52 AM
What kind of trace (which interface)? Maybe i could gve you some screenshot. Anyway i think help documents are quite ok to give yoi a starting point

kaizzer545
2010-10-20, 03:05 AM
yes, but i can not upload snapshot cause it is on the other machine, but in RNC i supposed that there is a slide call "trace" in that you can trace all links, I mean Gb, Abis, A, Ater, it depends what you want

Hope this be useful 4 u, regards

moh_sulaiman
2010-10-20, 09:35 PM
can some one share tool for analyses of traces.

br

salamanda1969
2010-10-25, 05:15 PM
Thanks Guys,

found out that we have to use the RNC LMT (not NodeB LMT) to trace calls. Will try it out soon.

Cheers

relaxrf
2011-01-09, 12:17 AM
there is Trace Viewer to read the data right?

mon3em
2011-01-09, 11:45 PM
there is Trace Viewer to read the data right?

there is a trace viewer within the LMT ... to view IOS, CDT, .....etc

But for CHR you need Omstar for RAN6
& for newer version of RAN (up to RAN12) you can read CHR by PCHR.


All above tools are here in forum .. just do a little bit search ... :)

thanhv2541
2011-02-18, 02:10 AM
only trace on LMT client, with M2000 can't trace

sonerss
2011-11-12, 11:09 PM
You can use LMT or PCHR

Laughing
2011-11-15, 12:49 AM
Hello engineers, Can someone provide guidelines or document on how to start a call trace in Huawei RNC or M2000 ? Many thanks. slm Hello, To trace a call, you need to have IMSI or MSISDN number. With BSC6000 or BSC6900, you can choose UE Trace for 3G or CS User Trace for 2G. It's simple action. Do you any request ?

essalvador
2011-11-16, 01:20 AM
there is a trace viewer within the LMT ... to view IOS, CDT, .....etc

But for CHR you need Omstar for RAN6
& for newer version of RAN (up to RAN12) you can read CHR by PCHR.




All above tools are here in forum .. just do a little bit search ... :)


excuse me but PCHR for R12 dost not be provided on the forum.

agenov
2011-11-16, 04:22 AM
There is but for very early version of RAN12 that is not applicable for the lastes one.


excuse me but PCHR for R12 dost not be provided on the forum.

essalvador
2011-11-16, 04:50 AM
There is but for very early version of RAN12 that is not applicable for the lastes one.

of course i have downloaded pchr from this forum i need the header decoder for R12 (*.xml) :)

dodotiro
2011-11-17, 04:03 PM
Hello, To trace a call, you need to have IMSI or MSISDN number. With BSC6000 or BSC6900, you can choose UE Trace for 3G or CS User Trace for 2G. It's simple action. Do you any request ?

you can follow my step as in attachment. i hope it can help you

didemir
2011-12-11, 02:46 AM
hi,
here waht we use for tracing :
22705
for 2G ue trace
at m200 for 2G use command DSP CALLRES. run command in the BSC that ue is in. you should use as IMSI or MSISDN of caller, not the number you will trace. This command also runs through LMT.

for 3G ue trace get in the RNC through LMT. at left bottom choose maintenance. then choose under service\realtime performance monitoring\connection performans monitoring