PDA

View Full Version : Ask Nokia Timing Advance



cormon
2010-01-27, 03:58 PM
Hi everyone,
can someone help me about how to generate timing advance report from OSS so that it has minimum range of 550 m (the smallest). I had problem since the report from ND 232 shown only from 1.1 km as the smallest range, while in our network now has site distance about 300m (inner city).
Is there any setup in the BSC needed for this ?

Please help.

Thanks.

cormon
2010-01-29, 03:43 PM
Hi everyone,
can someone help me about how to generate timing advance report from OSS so that it has minimum range of 550 m (the smallest). I had problem since the report from ND 232 shown only from 1.1 km as the smallest range, while in our network now has site distance about 300m (inner city).
Is there any setup in the BSC needed for this ?

Please help.

Thanks.

Anyone help please ........:L

gandhi_71
2010-01-29, 03:54 PM
Can you send ND 232 to me at my mail id bindastpyes@gmail.com

I will go thru it and make u understand

gandhi_71
2010-01-29, 03:59 PM
Hi,

I have checked my ND 232 and found that in my ND 232 there is .55Km rnage also mentioned.

BSC:BSC09CKN Segment: EBAJAJCHAKAN1 (1)

Distance Share
upper in min max ave
TRX EXT range Freq of range power power power
type (km) (km) reports (%) (dBm) (dBm) (dBm)
------ ---- -------- -------- ------- ------ ------ ------
normal 0 0.55 1765212 93.94 0 30
normal 0 1.10 45467 2.42 16 30
normal 0 2.20 42517 2.26 14 30
normal 0 3.30 12835 0.68 22 30
normal 0 4.40 359 0.02 30 30
normal 0 6.60 321 0.02 30 30
normal 0 8.80 1022 0.05 30 30
normal 0 11.00 2412 0.13 30 30
normal 0 17.60 9036 0.48 30 30
normal 0 34.65 0 0.00 -- -- --

Plz share your ND report here.

cormon
2010-01-29, 05:18 PM
Hi, thank u for your reply.
Here is my report example generated from oss:

gandhi_71
2010-01-29, 05:32 PM
Hi,

there is a MML command ZTPI by which you can get the infromation about Timing advance measurment table,
and with command ZTPM can modify the observation details.

You need to run ZTPM to get .55KM in your oss reports.

Hope this helps.

Regards.

nabil el haddani
2010-01-30, 03:18 AM
Hi bro,

Actually i don't have ND reporter, do u know how to do get the timing advance table with MML commands or with Nokia report builder??

Br,

Nabil

gandhi_71
2010-02-01, 12:16 PM
Here you go. ZPTI will give you the answer

TPI:MEASUR,TIMING_ADV

/* SELECT EXECUTION DETERMINATION OR
SYSTEM NAME OF OUTPUT DEVICE

EXECUTION DETERMINATION:
; .. COMMAND EXECUTION
N .. NO EXECUTION

SYSTEM NAME OF OUTPUT DEVICE:
1 ... 11 CHARACTERS

DEFAULT IS CURRENT DEFINITION */

TPI:MEASUR,TIMING_ADV:;

BSC3i BSC19JPD 2010-01-29 12:47:45

TYPE: TIMING_ADV

TIMING ADVANCE SUB RANGE 1 : 1
TIMING ADVANCE SUB RANGE 2 : 2
TIMING ADVANCE SUB RANGE 3 : 4
TIMING ADVANCE SUB RANGE 4 : 6
TIMING ADVANCE SUB RANGE 5 : 8
TIMING ADVANCE SUB RANGE 6 : 12
TIMING ADVANCE SUB RANGE 7 : 16
TIMING ADVANCE SUB RANGE 8 : 20
TIMING ADVANCE SUB RANGE 9 : 32

LAST MODIFIED: 2009-12-30 15:41:39
ADMIN. STATE: UNLOCKED
OPER. STATE: ENABLED
MEASUREMENT INTERVAL:
MON 08:00-22:00
TUE 08:00-22:00
WED 08:00-22:00
THU 08:00-22:00
FRI 08:00-22:00
SAT 08:00-22:00
SUN 08:00-22:00
START DATE: 2009-12-30
STOP DATE:
OUTPUT INTERVAL: 00:60


COMMAND EXECUTED

cormon
2010-02-01, 01:40 PM
Thanks a lot bro :D

I just found the problem based on that ZTPI command, it turn out that it was all set to default.

gandhi_71
2010-02-01, 04:39 PM
Good to know that I could be of any help. If Possible plz add to my reputation.

mojiiiiii
2010-08-30, 09:28 AM
hi
i dont have ND reports.
how i can calc TA Advance?

vinaysharma83
2011-04-14, 11:38 PM
Good to know that I could be of any help. If Possible plz add to my reputation.

good note
thanks

riyantoyadi
2011-04-14, 11:43 PM
every NSN OSS must be has ND Report. i think it's a default except your company not buying the licence

polo
2011-04-14, 11:59 PM
hi,
U can use scanctrx to evalaute TA,RXLEV & RXQUAL.