PDA

View Full Version : Question ask about MFRMS



agungcoml
2009-12-02, 05:11 PM
dear all,

i have question about MFRMS parameter, is it influence with paging rate?

thanks
agungcoml

wolverine
2009-12-03, 03:04 AM
BA-PA-MFRMS defines how often a particular MS will be paged. It can take values from 2 to 9 and the unit is a CCH multiframe (that lasts 235ms).

So if lets say you have set BA-PA-MFRMS to 3 then each MS (they are actually grouped) will be paged every 3 x 235ms = 705ms

agungcoml
2009-12-05, 07:02 PM
BA-PA-MFRMS defines how often a particular MS will be paged. It can take values from 2 to 9 and the unit is a CCH multiframe (that lasts 235ms).

So if lets say you have set BA-PA-MFRMS to 3 then each MS (they are actually grouped) will be paged every 3 x 235ms = 705ms

thanks mr markos....:)