PDA

View Full Version : BBH



justdream
2009-11-04, 02:35 AM
Friends,
I have a concern regarding BBH

from the drive test the hopping is active and I detected it
but in SET_BTS the HOPP value for this cell is False

what does it mean and how coem I have false in HOPP value while I detected it in Drive test

I have big Drop call rate in this cell

radenmohawk
2009-11-07, 08:03 PM
Hi,

Is this Siemens network?
Please consistency check hopping parameters such as on FHSYSID, MAIO, Hopping parameters per TRX, etc..
If still problem you can delete create configuration TRX / hopping on that cell.
and also check no hardware problem (CU, DUAMCO, semigid cable, etc)

thx

RF engineer
2009-11-08, 02:12 AM
Friends,
I have a concern regarding BBH

from the drive test the hopping is active and I detected it
but in SET_BTS the HOPP value for this cell is False

what does it mean and how coem I have false in HOPP value while I detected it in Drive test

I have big Drop call rate in this cell

mzy be there are problem in software may be it is bug restart the bts and check again