PDA

View Full Version : HW ENTITIES MISMTCH



idoorhigh
2014-01-02, 11:21 PM
Pls how do I clear this alarm, occurs on outdoor RBSs mostly

NumberOfHwEntitiesMismatch Cabinet=1 (SAU that is not configured detected.)

Rgds

Aidokhai

electron
2014-01-02, 11:35 PM
Check FAN and PSU on RBS side either some does not work or configured mistakenly.


Cheers
Pls how do I clear this alarm, occurs on outdoor RBSs mostly

NumberOfHwEntitiesMismatch Cabinet=1 (SAU that is not configured detected.)

Rgds

Aidokhai

idoorhigh
2014-01-03, 12:44 AM
Can this be resolved remotely???


Check FAN and PSU on RBS side either some does not work or configured mistakenly.


Cheers

spiderman
2014-02-09, 01:00 AM
What kind RBS Type Bro? I usually just disable SAU from element manager equipment. Maybe your SAU is faulty, or is there any aquipment in one subrack? trying to be master and slave on external node parameter :-)

mrsammr
2014-02-09, 05:56 PM
Do you have sau in this RBS or not? If there is you would have to add it, if you haven't you would have to remove from omt or RBS element mánager. If it's duw it can be done remotely, i think

Good luck