PDA

View Full Version : Does anyone know how to check for software version of node B and its RNC?



shamu.seaworld
2012-12-15, 07:24 AM
Please help if you can...thank you

electron
2012-12-15, 12:57 PM
In E/// system run command "cvcu" in both nodes you will see SW version
Please help if you can...thank you

uchok
2013-03-13, 11:02 AM
For more detail please see below :
XXXXX> cvcu

===================================================================================================================
130312-20:30 CV Name Upgrade Package Release
===================================================================================================================
Startable: Au_CXP9016865%1_R9F01_130312_0300 CXP9016865/1_R9F01 W11GPBCBU (EP56-CPP_8.0.1.1)
Loaded: Test_CXP9016865%1_R9F01_130306_2009 CXP9016865/1_R9F01 W11GPBCBU (EP56-CPP_8.0.1.1)
Executing: Au_CXP9016865%1_R9F01_130312_0300 CXP9016865/1_R9F01 W11GPBCBU (EP56-CPP_8.0.1.1)
Last created: Au_CXP9016865%1_R9F01_130312_0300 CXP9016865/1_R9F01 W11GPBCBU (EP56-CPP_8.0.1.1)
-------------------------------------------------------------------------------------------------------------------
Current UpgradePkg: UpgradePackage=CXP9016865/1_R9F01 CXP9016865/1_R9F01 W11GPBCBU (EP56-CPP_8.0.1.1)
AutoCreatedCV: Enabled. Daily backup at 03:00
Countdown status: Deactivated
Ongoing CV activity: 0 (IDLE)
Rollback status: Rollback is on
Rollback init timer: 30
Rollback init counter: 2
Rollback counter: 2

For the current software version its using you can check "Current UpgradePkg". There you'll see the software release, in this case is "W11GPBCBU (EP56-CPP_8.0.1.1)"


Please help if you can...thank you