please help me with clear explain..

what difference RX lev Sub and RX lev Full..
what difference RXqual Sub and RX qual Full..

why for check coverage we need use Idle Mode not Dedicated Mode.

thanks.

cocoloco
2010-06-15, 06:42 PM
Rxlev_Full & RxQual_Full : Measurements taken over full set of TDMA frames
Full set of TDMA frames : 102 for SDCCH
Full set of TDMA frames : 104 TCH

Rxlev_Sub & RxQual_Sub : Measurements taken over subset of TDMA frames
If even one frame is not transmitted in the measurement period, then it is considered as subset of TDMA frames.


Sub Measurements are done in these cases:

When DTX used, and the receiver enters the DTX mode , then the measurement is done over all the frames is not valid.
With DTX, if there is completely no speech for 480ms, then still there will be 8 frames of SID and 4 frames of SACCH, these 12 subset frames will be used for sub measurements .
DTX is not used on BCCH carrier (all timeslots) , hence if the call is on a TCH which is on a BCH carrier, then it will always be FULL, and in the measurement report both Sub and Full values will be same.
DTX is not used on the SDCCH also , hence the above clause applies to this also.
On a TCH carrier, when DTX was used by the BTS in the previous 480ms period, measurement is Sub, else it is full.
If Frequency Hopping was used, and BCH carrier was a part of it, and dowlink power control is used, then the measurements for Rx_Lev will always be sub ( since BCH carrier frames are not included in the measurement averaging)

josogun2
2010-06-15, 07:16 PM
see the attached doc for more info.
thanks

diankestiwi
2010-06-15, 07:48 PM
Thankf for Mr Coco and Mr Josogun.. but your data use pass...
may i know the pass...

josogun2
2010-06-15, 08:11 PM
@diankestiw
check ur PM for pass

nevy_14
2010-06-16, 04:53 AM
If Frequency Hopping was used, and BCH carrier was a part of it, and dowlink power control is used, then the measurements for Rx_Lev will always be sub ( since BCH carrier frames are not included in the measurement averaging)

hi cocoloco,

from your post above, so if the call is located at hopping trx then the measurement should be in sub?
please explain...

BR,
nevy_14

josogun2
2010-06-16, 08:03 PM
@nevy_14
Attached doc explain everything

josogun2
2010-06-21, 05:25 PM
hope all is clear now?

nevy_14
2010-06-21, 05:35 PM
hope all is clear now?