PDA

View Full Version : E******* BSC capacity need help



cocola
2010-06-11, 12:30 PM
Dear bros.
Can anyone please help me to calculate the exactly number of TRXs that one BSC (APG40, APZ212 33) handled?
As I know, one RPG3 can handle 32 TRX. But this depend on the parameter : MAXNOSDCCHTRX and LAPD concentration factor. So how can we calculate the exactly number of TRXs from the two parameters?
Thanks and best regards.

cocola
2010-06-12, 12:41 PM
no one help me :L

hieuvnp3
2010-06-14, 02:54 PM
you can read in alex, search Hardware dimensioning.

s52d
2010-06-18, 04:48 AM
Is it 212-33 or 212-33C

212-33C: If you go well beyond some 1300 TRXes, you might face problems with
paging on A interface.

You need optional features as well: having too much neighbor relations, number of cells etc.

Of course, all the rest shall have this capacity.

Anyhow, with some care it might be pushed to 2000 TRXes.

cocola
2010-06-18, 09:59 AM
thanks my dear.

roloramos
2010-11-19, 11:06 PM
You can take a mean value...
RPG3 * 31 TRX
RPG2 * 19 TRX
Are very useful values

But, i attached the values that the vendor recomends...